top of page

Features

Customization for industrial telephones

01.

Based in Pennsylvania, USA

02.

Free Shipping: 10-17 Business Days in US, Canada & Europe & Worldwide

03.

2-Year Full Warranty + 10-Day Global Spare Parts Delivery. 

04.

Support with Equipment Selection, Design & Installation

05.

Custom Options: Color, Labels, Strobe Lights, Horns & More

LCEX-WL Explosion-Proof Beacon

 

Hazardous area warning light for industrial safety, emergency signaling, and explosion-proof communication systems.

 

The LCEX-WL Explosion-Proof Beacon is a rugged visual warning device designed for hazardous industrial environments where reliable visual signaling is required. It can be used as an additional signal device with explosion-proof telephone systems, gas detection systems, safety alarm systems, public warning systems, and industrial emergency notification equipment.

This beacon is designed for sites where a standard warning light is not suitable due to explosive gas, dust, harsh weather, vibration, corrosion, or heavy industrial conditions.

 

Who is it for?

The LCEX-WL is suitable for:

  • Oil & gas facilities
  • Refineries
  • Petrochemical plants
  • Chemical processing sites
  • LNG and natural gas facilities
  • Offshore and onshore drilling platforms
  • Marine and port facilities
  • Power plants
  • Utility tunnels
  • Mining and heavy industrial sites
  • Hazardous production areas
  • Industrial safety and alarm systems

 

The problem it solves

In hazardous areas, workers may not hear an alarm, phone ring, or voice announcement clearly due to high ambient noise, machinery, distance, or hearing protection.

The LCEX-WL Explosion-Proof Beacon provides a clear visual warning signal to help draw attention to alarms, incoming calls, emergency events, gas detection warnings, or safety system activations.

It is especially useful when a visual signal is required together with explosion-proof phones, horns, loudspeakers, or alarm systems.

 

Why choose LCEX-WL?

  • Explosion-proof visual warning beacon for hazardous areas
  • Designed for industrial alarm and emergency notification systems
  • Suitable for use with explosion-proof telephones and safety systems
  • LED long-on, flashing, rotating, and xenon flashing function options
  • Light sensor switch function with adjustable light level
  • IP66 protection rating
  • Explosion-proof standard: Ex d ib IIC T6 Gb / Ex tD A21 IP66 T80°C
  • ATEX and IECEx explosion-proof certification
  • Aluminum alloy or stainless steel housing options
  • Corrosion-resistant and impact-resistant construction
  • Easy installation and maintenance
  • Replaceable lamp head design

The original LCEX-WL product page lists LED long-on, flashing, rotating and xenon flashing functions, an adjustable light sensor switch, IP66 protection, ATEX/IECEx certification, and aluminum alloy or stainless steel housing options.

 

Typical applications

Use the LCEX-WL Explosion-Proof Beacon for:

  • Visual alarm indication in hazardous areas
  • Incoming call indication for explosion-proof telephone systems
  • Gas detection warning systems
  • Safety alarm systems
  • Public broadcast warning systems
  • Aviation obstruction warning applications
  • Emergency shutdown or evacuation signaling
  • Industrial process alarm indication
  • Remote hazardous-area safety points

 

Compatible LightCom solutions

The LCEX-WL can be used as part of a complete hazardous-area communication or alarm package:

Explosion-Proof Emergency Communication Station

  • LC106EX explosion-proof telephone
  • LCEX-WL explosion-proof beacon
  • Explosion-proof horn or loudspeaker
  • Explosion-proof junction box

 

Hazardous Area Visual Alarm Point

  • LCEX-WL explosion-proof beacon
  • Gas detection or safety alarm system
  • Local power and control interface

 

Oil & Gas / Petrochemical Warning System

  • Explosion-proof beacon
  • Audible alarm or horn
  • Public address or emergency notification system

 

Technical Highlights

  • Product type: Explosion-Proof Beacon / Hazardous Area Warning Light
  • Operating voltage: DC 12V
  • Power consumption: 10W
  • Protection rating: IP66
  • Housing material: aluminum alloy or SUS304 stainless steel optional
  • Lamp cover: ABS, corrosion-resistant and high-temperature resistant
  • Operating temperature: –30°C to +70°C
  • Operating humidity: 10%–95% RH, non-condensing
  • Dimensions: 149 × 149 × 188.35 mm
  • LED service life: ≥ 60,000 hours
  • Certifications: ATEX / IECEx explosion-proof certification
  • Explosion-proof standard: Ex d ib IIC T6 Gb / Ex tD A21 IP66 T80°C

 

Flashing / Warning Modes

Depending on configuration, the LCEX-WL may support:

  • LED steady-on mode
  • LED flashing mode
  • LED rotating beacon mode
  • Xenon strobe mode
  • 1Hz flash / 60 flashes per minute
  • 1.5Hz flash / 90 flashes per minute
  • 2Hz flash / 120 flashes per minute
  • Double-strike or triple-strike flash patterns
  • High-power or low-power steady LED mode

 

Installation & Maintenance

The LCEX-WL is designed for straightforward installation and field maintenance in harsh industrial environments. Installation features:

  • Surface-mounted explosion-proof beacon
  • Suitable for wall, structure, equipment frame, or dedicated mounting bracket installation
  • Designed for hazardous-area alarm and signaling systems
  • Can be used as a standalone visual warning light or as an additional signal device with explosion-proof telephones, gas detectors, PA/warning systems, and safety alarm systems
  • Rugged aluminum alloy or SUS304 stainless steel housing options
  • Replaceable lamp head for easier maintenance
  • On-site parameter configuration supported
  • Designed for outdoor and industrial use with IP66 protection

 

 

Where should I use a beacon instead of a horn?

Use an explosion-proof beacon when workers need a visual signal, especially in:

  • high-noise areas;
  • locations where hearing protection is used;
  • outdoor industrial areas;
  • zones with machinery noise;
  • areas where visual confirmation of alarm status is important.

Use a horn or audible alarm when an audible warning is required.

Use both beacon + horn when the site requires both visual and audible alerting.

 

Is this a siren or a beacon?

The LCEX-WL is an explosion-proof beacon, meaning it is primarily a visual warning light.

It is not the same as an audible siren.
For sound warning, use an explosion-proof audible alarm, horn, or audible/visual alarm model.

 

Order Information

LCEX-WL Explosion-Proof Beacon / Hazardous Area Warning Light
For industrial safety, alarm signaling, explosion-proof communication systems, and hazardous-location visual notification.

LCEX-WL Explosion-Proof Beacon

$745.00Price
Excluding Sales Tax
Quantity
  • Product Type:
    Explosion-Proof Beacon / Hazardous Area Warning Light

    Application:
    Visual warning device for explosion-proof telephone systems, gas detection systems, industrial safety alarms, public broadcast warning systems, and hazardous-area emergency notification systems.

    Explosion-Proof Standard:
    Ex d ib IIC T6 Gb / Ex tD A21 IP66 T80°C

    Certifications:
    ATEX / IECEx explosion-proof certification

    Protection Rating:
    IP66

    Operating Voltage:
    DC 12V

    Power Frequency:
    50Hz–60Hz

    Power Consumption:
    10W

    Light Source Options:

    • LED reflector rotating type
    • LED flashing & strobe type: 5W / 10W
    • Xenon strobe type: 5J / 10J / 15J / 20J

    Rotation Speed:
    120–140 RPM

    Warning Modes:

    • Rotating beacon
    • 1Hz flash — 60 flashes per minute
    • 1.5Hz flash — 90 flashes per minute
    • 2Hz flash — 120 flashes per minute
    • Double-strike flash: 50ms on, 150ms off × 2, 600ms off
    • Triple-strike flash: 150ms on, 150ms off × 3, 600ms off
    • High-power steady mode
    • Low-power steady mode

    LED Service Life:
    ≥ 60,000 hours

    Housing Material:
    Aluminum alloy or SUS304 stainless steel

    Lamp Cover Material:
    ABS, corrosion-resistant and high-temperature resistant

    Operating Temperature:
    -30°C to +70°C
    -22°F to +158°F

    Operating Humidity:
    10%–95% RH, non-condensing

    Product Dimensions:
    149 × 149 × 188.35 mm
    5.87 × 5.87 × 7.42 in

    Installation / Maintenance:
    Easy to install, maintain, configure on site, and replace the lamp head.

Related Products

CLIENTS

Tested and Trusted by Leading Industries

b3313396-fb21-4890-bbb2-ded65e0e2092.png
US Coast Guard.png
arcelormittal-logo.png
marriott-hotels-resorts-logo-png-transparent.png

Verified. Certified. Trusted.

Avaya-devconnect-tested-letter.png
120170912_0005.jpg
BV-main-product-219x300.jpg
13.jpg
QQ截图20190916092241-213x300 (1).jpg
QQ截图20190916092001-214x300.jpg
bottom of page